Workflow

<< Click to Display Table of Contents >>

Navigation:  DeltaShowControlInterface >

Workflow

1.Install DeltaShowControlInterface software on the Delta Server or another networked PC where you wish to use it.

2.Connect the Advantech ADAM-6060 to the server Ethernet network.*

Click for a larger image

3.Connect and switch on the power supply.

4.Install and run the Adam/Apax .NET utility on the Delta server playing the shows to be controlled.

5.Configure the ADAM-6060 comms so that the Delta server and the ADAM-6060 talk to each other.

6.Connect the switches to be used with the Digital Inputs on the ADAM-6060:*

Click for a larger image

7.Configure DeltaShowControlInterface so that DeltaServer communicates with it.

8.In DeltaGUI, configure the Delta show(s) to communicate with DeltaShowControlInterface, and/or create sequences with the sequential names that are integral to DeltaShowControlInterface. Which of these two modes is used is set in the Control Logic of DeltaShowControlInterface.

* Note. The Advantech ADAM-6060 is a very versatile unit being used in a very specific way with the DeltaShowControlInterface utility to provide simple show control switching for Delta servers using the digital inputs.

Shown here are connections that include the relay outputs. It is also possible to send ASCIIUDP from a Delta sequence to operate a relay switch for other equipment. This does not require the DeltaShowControlInterface. See Appendix: Sending ASCII to ADAM-6060.

Page edited [d/m/y]: 15/12/2020